Buka jam 08.00 s/d jam 17.00 , Minggu libur
Beranda » Incinerator

Incinerator

Incinerator Cap. : 0.01 m�/hour

incinerator-01

Type of Waste : Medical Waste
Incinerator Capacity : 0.01 m�/hour
Incinerator Type : Single Chamber
Operation Time : 8 hour/day
Chamber Volume : – 1st Chamber 0.024 m�
Incinerator Dimension (Outter ) : L0.47 x W0.32 x H1.67 m
Burner: 1st Burner 5 � 10 liter / hour, Light Oil Burner, Qty : 1 unit
Chamber Temperature : Chamber �900�C
Chamber Pressure : Negatif (Under Atmosferic Pressure)
Exaust Stack
– Diameter : 4 inchi
– Height : � 2 m.from ground level
– Coating : High Temp.Paint
Refractory Construction :
– Fire Brick : Fire Brick SK 32
– Castable : CAJ-12
Chamber Insulation
– 1st Wall : Fire Brick, SK-32
– 2nd Wall : Ceramic Fibre, 128 kg/m�
– Bottom : Insulating Brick
Shell & Structure Material Chamber :
– Shell Plate t.3 mm ,Mild Steel
– Joint Flange t.10 mm
– Burner Port t.8 mm
– Structure UNP 80 &
– Coating : Epoxy Paint
FDF Blower : Sentrifugal ,2500 CMH, 220/50,2800 rpm, 1 unit
Electric Power Requirement : 3 kW. 380 V. 3 PH
Fuel : Diesel Oil ( Solar )
Fuel Consumption : Max.10 liter / hour
Fuel Tank :
– Cap. 10 ltr
– Material Tank : Mild Steel plate t. 3 mm
– Level Control
– Drain Port
Control System :
– ELC
– Temperature Control : Digital
– Thermocouple : Type � K.
– Limit Switch
Ash : 5 � 10 % waste weight
Ash Discharging : Manual
Feeding System : Manual
Warranty Term : One year ( Service)
Operator Requirement : 1 Person
Area Requirement : 2 x 3 m

 

Incinerator Cap. 0.05 m�/hour

incinerator-05

Type of Waste : Medical Waste
Incinerator Capacity : 0.025 � 0.05 m�/hour
Incinertor Type : Single Chamber
Operation Time : 8 hour/day
Chamber Volume : – 1st Chamber 0.07 m�
Incinerator Dimension (Outter) :L0.6 x W 0.6x H 1.2 m
Burner : – 1st Burner 5 � 10 liter / hour, Light Oil Burner, Qty : 1 unit
Chamber Temperature : – 1st Chamber 400 – 800�C
Chamber Pressure : Negatif (Under Atmosferic Pressure)
Exaust Stack :
Diameter : 250 mm
Height : � 4 m.from ground level
Coating : High Temp.Paint
Refractory Construction
– Fire Brick SK34
– Castable CAJ-14
Chamber Insulation
– 1st Wall : Fire Brick, SK-34
– 2nd Wall : Ceramic Fibre, 128 kg/m�
– Bottom : Insulating Brick
Shell & Structure Material Chamber :
– Shell Plate t.3 mm ,Mild Steel
– Joint Flange t.12 mm
– Burner Port t.8 mm
– Structure UNP 80 &
– Coating : Epoxy Paint
FDF Blower : Sentrifugal ,2500 CMH, 220/50,2800 rpm, 1 unit
Electric Power Requirement : 5 kW. 380 V. 3 PH
Fuel : Diesel Oil ( Solar )
Fuel Consumption : Max.20 liter / hour
Fuel Tank :
– Cap. 50 ltr
– Material Tank : Mild Steel plate t. 3 mm
– Level Control
– Drain Port
Control System :
– ELC
– Temperature Control : Digital
– Thermocouple : Type � K.
– Limit Switch
Ash : 5 � 10 % waste weight
Ash Discharging : Manual
Feeding System : Manual
Warranty Term : One year ( Service)
Operator Requirement : 1 Person
Area Requirement : 2 x 3 m


Incinerator Cap. 0.3 m�/Hourr

incinerator-03

Type of Waste : Medical Waste
Incinerator Capacity : 0.3 m�/hour
Incinerator Type : Single Chamber
Operation Time : 8 hour/day
Chamber Volume : 1st Chamber 0.35 m�
Incinerator Dimension (Outter) : L1.22 x W0.96 x H1.12 M
Burner : -1st Burner 5 � 10 liter / hour, Light Oil Burner, Qty : 1 unit
Chamber Temperature : -1st Chamber �800�C – 1200�C
Chamber Pressure : Negatif (Under Atmosferic Pressure)
Exaust Stack Diameter :
– � 250 mm
– Height : � 4 m.from ground level
– Coating : High Temp.Paint
Refractory Construction :
– Fire Brick : Fire Brick SK 32
– Castable : CAJ-12
Chamber Insulation :
– 1st Wall : Fire Brick, SK-32
– 2nd Wall : Ceramic Fibre, 128 kg/m�
– Bottom : Insulating Brick
Shell & Structure Material Chamber :
– Shell Plate t.3 mm ,Mild Steel
– Joint Flange t.10 mm
– Burner Port t.8 mm
– Structure UNP 80 &
– Coating : Epoxy Paint
Wet Scrubber :
– � 0.38 x 0.6 mm
– Material : t,2 mm,stainless
– Spray nozzle
– Spray Pump : � 20 � 40 liter / menit
– Power : 1 HP / 220 V / 50 Hz
FDF Blower : Sentrifugal ,2500 CMH, 220/50,2800 rpm, 1 unit
Electric Power Requirement : 3 kW. 380 V. 3 PH
Fuel: Diesel Oil ( Solar )
Fuel Consumption : Max.10 liter / hour
Fuel Tank :
– Cap. 60 ltr
– Material Tank : Mild Steel plate t. 3 mm
– Level Control
– Drain Port
Control System :
– ELC
– Temperature Control : Digital
– Thermocouple : Type � K.
– Limit Switch
Ash : 5 � 10 % waste weight
Ash Discharging : Manual
Feeding System : Manual
Warranty Term : One year ( Service)
Operator Requirement : 1 Person
Area Requirement : 3 x 3 m


Incinerator Cap.20 kg/Hour

incinerator-20

Type of Waste : Bulk Density :� 0.1 � 0.15 kg/m�
Incinerator Type : Medical Waste
Incinerator Capacity : 20 kg/hour Multiple Chamber
Operation Time : 8 hour/day
Chamber Volume :
– 1st Chamber : 0.5 m�
– Mixing Room : 0.1 m�
– Second Chamber : 0.2 m�
Incinerator Dimension (Outter) : L:1.50 X W:1.2 X H:1.6 m
Burner :
– 1st Burner : 5 � 10 liter / hour, Light Oil Burner, Qty : 1 unit
– 2nd Burner : 5 �10 liter / hour, Light Oil Burner, Qty : 1 unit
Chamber Temperature :
– 1st Chamber : 600 – 800�C
– 2nd Chamber : 800- 1000�C
Chamber Pressure : Negatif (Under Atmosferic Pressure)
Exaust Stack :
– Diameter : 350mm (1st Stack),�200 mm (2nd Stack)
– Height : �8 m.from ground level
– Sampling Port �3�
– Coating : High Temp.Paint
Refractory Construction :
– Fire Brick : Fire Brick SK 34
– Castable : CAJ-14
Chamber Insulation :
– 1st Wall : Fire Brick, SK-34
– 2nd Wall : Ceramic Fibre, 128 kg/m�
– 3rd Wall : Rockwool,60 kg/m�
– 4th Wall : Glaswool, 20 kg/m�
– 5th Wall : Shell Plate
– Bottom : Insulating Brick
Shell & Structure Material Chamber :
– Shell Plate t.4 mm ,Mild Steel
– Joint Flange t.12 mm
– Burner Port t.8 mm
– Plenum Plate t.3 mm
– Structure UNP 80 & UNP 50
– Lifter t.12 mm
– Coating : Epoxy Paint
FDF Blower : Sentrifugal ,2500 CMH, 380/50,2800 rpm, 1 unit
Electric Power Requirement : 5 kW. 380 V. 3 PH
Fuel : Diesel Oil ( Solar )
Fuel Consumption : Max.15 liter / hour
Fuel Tank :
– Cap. 250 ltr
– Material Tank : Mild Steel plate t. 4 mm
– Level Control
– Drain Port
Control System :
– ELC
– Temperature Control : Digital
– Thermocouple : Type � K.
– Limit Switch
Ash : 5 � 10 % waste weight
Ash Discharging : Manual
Feeding System : Manual
Warranty Term : One year ( Service)
Operator Requirement : 1 Person
Area Requirement : 4 x 3 m
Emision Quality : Smokeless
According to Goverment : CO < 100 mg/Nm3
Regulation : NO2 < 300 mg/Nm3, Opacity < 10 %


Incinerator Cap.30 kg/Hour

incinerator-30

Type of Waste : Bulk Density :� 0.1 � 0.15 kg/m�
Incinerator Type : Medical Waste
Incinerator Capacity : 30 kg/hour (0,3m�/h)   Multiple Chamber, Retort System
Operation Time : 8 hour/day
Chamber Volume :
– 1st Chamber : 1.0 m�
– Mixing Room : 0.1 m�
– Second Chamber : 0.2 m�
Incinerator Dimension (Outter) : L:1.8 X W:1.4 X H:1.6 m
Burner :
– 1st Burner : 5 � 10 liter / hour, Light Oil Burner, Qty : 1 unit
– 2nd Burner : 5 �10 liter / hour, Light Oil Burner, Qty : 1 unit
Chamber Temperature :
– 1st Chamber : 600 – 800�C
– 2nd Chamber : 800- 1000�C
Chamber Pressure : Negatif (Under Atmosferic Pressure)
Exaust Stack :
– Diameter : 400mm (1st Stack),�250 mm (2nd Stack)
– Height : �8 m.from ground level
– Sampling Port �3�
– Coating : High Temp.Paint
Refractory Construction :
– Fire Brick : Fire Brick SK 34
– Castable : CAJ-14
Chamber Insulation :
– 1st Wall : Fire Brick, SK-34
– 2nd Wall : Ceramic Fibre, 128 kg/m�
– 3rd Wall : Rockwool,60 kg/m�
– 4th Wall : Glaswool, 20 kg/m�
– 5th Wall : Shell Plate
– Bottom : Insulating Brick
Shell & Structure Material Chamber :
– Shell Plate t.3 mm ,Mild Steel
– Joint Flange t.12 mm
– Burner Port t.6 mm
– Plenum Plate t.3 mm
– Structure UNP 80 & UNP 50
– Lifter t.12 mm
– Coating : Epoxy Paint
FDF Blower : Sentrifugal (6-12 mm Aq), 14m�/min, Qty : 1 unit
Electric Power Requirement : 5 kW. 380 V. 3 PH
Fuel : Diesel Oil ( Solar )
Fuel Consumption : Max.20 liter / hour
Fuel Tank :
– Cap. 250 ltr
– Material Tank : Mild Steel plate t.3 mm
– Level Control
– Drain Port
Control System :
– PLC/ELC
– Temperature Control : Digital
– Thermocouple : Type � K.
– Limit Switch
Ash : 5 � 10 % waste weight
Ash Discharging : Manual
Feeding System : Manual
Warranty Term : One year ( Service)
Operator Requirement : 1 Person
Area Requirement : 5 x 4 m
Emision Quality : Smokeless
According to Goverment : CO < 100 mg/Nm3
Regulation : NO2 < 300 mg/Nm3, Opacity < 10 %

 

Insinerator Cap.50 kg/Hour

incinerator-50

Type of Waste : Bulk Density :� 0.1 � 0.15 kg/m�
Incinerator Type : Domestic Waste
Incinerator Capacity : 50 kg/hour (0,3m�/h)   Multiple Chamber, Retort System
Operation Time : 8 hour/day
Chamber Volume :
– 1st Chamber : 1.7 m�
– Mixing Room : 0.4 m�
– Second Chamber : 1.0 m�
Incinerator Dimension (Outter) : L:2.1 X W:2.0 X H:1.9 m
Burner :
– 1st Burner : 10 � 20 liter / hour, Light Oil Burner, Qty : 1 unit
– 2nd Burner : 10 �20 liter / hour, Light Oil Burner, Qty : 1 unit
Chamber Temperature :
– 1st Chamber : 600 – 900�C
– 2nd Chamber : 800- 1000�C
Chamber Pressure : Negatif (Under Atmosferic Pressure)
Exaust Stack :
– Diameter : 250mm stainles steel,
– Height : �8.5 m.from ground level
– Sampling Port �3�
– Sampling Platform
Scrubber :
– Diametre : 0.77 mm (Outer)
– Height : 2.9 m (Outer)
Material Scrubber :
– Body Plate : SUS � 304, t.3 mm
– Frame : UNP profile
– Piping : SUS � 304 � 2�
– Nozzle : � ��,Stainless steel
Spray Pump :
– Grundfos,CHI 4-20/750 ltr/hr
– Power : 0.38 kW/1 phase/Multistages/Stainless
Refractory Construction :
– Fire Brick : Fire Brick SK 34
– Castable : CAJ-14
Chamber Insulation :
– 1st Wall : Fire Brick, SK-34
– 2nd Wall : Ceramic Fibre, 128 kg/m�
– 3rd Wall : Rockwool,60 kg/m�
– 4th Wall : Glaswool, 20 kg/m�
– 5th Wall : Shell Plate
– Bottom : Insulating Brick
Shell & Structure Material Chamber :
– Shell Plate t.4 mm & 6mm. Mild Steel
– Joint Flange t.12 mm
– Burner Port t.8 mm
– Plenum Plate t.3 mm
– Structure UNP 100 & UNP 80
– Lifter t.16 mm
FDF Blower : Sentrifugal,2500 CMH,2800Rpm,1100 Watt,380/50. 2 unit
Electric Power Requirement : 5 kW. 380 V. 3 PH
Fuel : Diesel Oil ( Solar )
Fuel Consumption : Max.40 liter / hour
Fuel Tank :
– Cap. 500 ltr
– Material Tank : Mild Steel plate t.3 mm
– Drain Port
Control System : ELC
Ash : 5 � 10 % waste weight
Ash Discharging : Manual
Feeding System : Manual
Warranty Term : One year ( Service)
Operator Requirement : 1 Person
Area Requirement : 6 x 6 m
Emision Quality : Smokeless
According to Goverment : CO < 100 mg/Nm3
Regulation : NO2 < 300 mg/Nm3, Opacity < 10 %

 

Insinerator Cap.100 kg/Hour

incinerator-100

Type of Waste : Bulk Density :� 0.1 � 0.15 kg/m�
Incinerator Type : Medical Waste
Incinerator Capacity : 100 kg/hour (0,3m�/h)   Multiple Chamber, Retort System
Operation Time : 8 hour/day
Chamber Volume :
– 1st Chamber : 2.5 m�
– Mixing Room : 0.5 m�
– Second Chamber : 1.2 m�
Incinerator Dimension (Outter) : L:2.5 X W:1.4 X H:2.2 m
Burner :
– 1st Burner : 10 � 15 liter / hour, Light Oil Burner, Qty : 2 unit
– 2nd Burner : 10 �20 liter / hour, Light Oil Burner, Qty : 1 unit
Chamber Temperature :
– 1st Chamber : 600 – 800�C
– 2nd Chamber : 800 – 1000�C
Chamber Pressure : Negatif (Under Atmosferic Pressure)
Exaust Stack :
– Diameter : 500mm
– Height : �10 m.from ground level
– Sampling Port �3�
– Sampling Platform
– Lining Castable for insulating.
Refractory Construction :
– Fire Brick : Fire Brick SK 34
– Castable : CAJ-14
Chamber Insulation :
– 1st Wall : Fire Brick, SK-34
– 2nd Wall : Ceramic Fibre, 128 kg/m�
– 3rd Wall : Rockwool,60 kg/m�
– 4th Wall : Glaswool, 20 kg/m�
– 5th Wall : Shell Plate
– Bottom : Insulating Brick
Shell & Structure Material Chamber :
– Shell Plate t.4 mm & 6mm. Mild Steel
– Joint Flange t.12 mm
– Burner Port t.8 mm
– Plenum Plate t.3 mm
– Structure UNP 120 & UNP 80
– Lifter t.16 mm
FDF Blower : Sentrifugal,4500 CMH,2800Rpm,2200Watt. Qty : 2 unit
Electric Power Requirement : 5 kW. 380 V. 3 PH
Fuel : Diesel Oil ( Solar )
Fuel Consumption : Max.40 liter / hour
Fuel Tank :
– Cap. 500 ltr
– Material Tank : Mild Steel plate t.4 mm
– Drain Port
Control System : ELC
Ash : 5 � 10 % waste weight
Ash Discharging : Manual
Feeding System : Manual
Warranty Term : One year ( Service)
Operator Requirement : 1 Person
Area Requirement : 7 x 5 m
Emision Quality : Smokeless
According to Goverment : CO < 100 mg/Nm3
Regulation : NO2 < 300 mg/Nm3, Opacity < 10 %

Bagikan informasi tentang Incinerator kepada teman atau kerabat Anda.

Incinerator | Mesin Pertanian – Pabrik Alat Pertanian, Mesin Pertanian

Temukan Kami
Sidebar Kiri
Kontak
Cart
Sidebar Kanan